NIOSH Analytical Method, Stibine, Sampling Data Sheet, S243 (Set 2).

Authors
NIOSH
Source
NIOSH 1977 Jul:3 pages
Link
NIOSHTIC No.
00076514
Abstract
The data sheet is given for the sampling of stibine (7803523) in the air and includes a brief summary of the analytical method, sampling equipment, sample size, sampling procedure, special considerations, and shipping instructions. A sample size of 18 liters is recommended with a sample flow rate of 0.2 liter per minute or less for 90 minutes. Special considerations include interference by americium-(III) (7440359), gold (7440575), iron-(III) (7439896), thallium-(I) (7440280), and tin-(II) (7440315); recharging sampling battery at least every eight hours; and water condensation on the solid sorbent.
Keywords
NIOSH-Author; NIOSH-Analytical-Method; Standards-Completion-Program; SCP; Analytical-Method; Standards; Sampling; Set-2; Air-quality-measurement; Air-sampling; Procedures; Antimony-compounds; Metal-compounds;
CAS No.
7803-52-3; 7440-35-9; 7440-57-5; 7439-89-6; 7440-28-0; 7440-31-5;
Publication Date
19770701
Fiscal Year
1977
NTIS Accession No.
NTIS Price
Identifying No.
S243
NIOSH Division
DPSE;
Source Name
Division of Physical Sciences and Engineering, NIOSH, Cincinnati, Ohio, 3 pages, 1 reference