NIOSH Analytical Method, Allyl Glycidyl Ether, Sampling Data Sheet, S346, (Set 2).

Authors
NIOSH
Source
NIOSH 1977 Jul:2 pages
Link
NIOSHTIC No.
00076492
Abstract
The data sheet is given for the sampling of allyl-glycidyl-ether (106923) in the air and includes a brief summary of the analytical method, sampling equipment, sample size, sampling procedure, special considerations, and shipping instructions. A sample size of 3 liters is recommended with a sample flow rate of 0.2 liter per minute for 15 minutes. Special considerations include full recharging the battery of the sampling pump at least every eight hours and noting the breakthrough capacity of 12 liters.