NIOSH Analytical Method, Zinc Oxide Fume, Sampling Data Sheet, S316, (Set 3).

Authors
NIOSH
Source
NIOSH 1977 Nov:2 pages
Link
NIOSHTIC No.
00076490
Abstract
The data sheet is given for the sampling of zinc-oxide (1314132) fume in air and includes a brief summary of the analytical method, sampling equipment, sample size, sampling procedure, special considerations, and shipping instructions. A sample size of 180 liters is recommended with a sample flow rate of 1.5 liters per minute for 120 minutes. Special considerations include several compounds, such as zinc (7440666), which would cause serious interference.
Keywords
NIOSH-Author; NIOSH-Analytical-Method; Standards-Completion-Program; SCP; Analytical-Method; Standards; Sampling; Set-3; Air-quality-measurement; Air-sampling; Procedures; Oxides; Heavy-metals; Zinc-oxide-fume;
CAS No.
1314-13-2; 7440-66-6;
Publication Date
19771101
Fiscal Year
1978
NTIS Accession No.
NTIS Price
Identifying No.
S316
NIOSH Division
DPSE;
Source Name
Division of Physical Sciences and Engineering, NIOSH, Cincinnati, Ohio, 2 pages, 1 reference
State
OH;