Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

NIOSH Analytical Method, Dinitrotoluene, Backup Data Report S215, (Set 3).

Authors
NIOSH
Source
NIOSH 1977 Nov:17 pages
Link
NIOSHTIC No.
00076477
Abstract
The backup data report is given for validating the method for determining dinitrotoluene (121142) in the air. Samples were analyzed regarding collection efficiency of the cellulose ester membrane filter connected in series to a backup bubbler, the storage stability, and the precision and accuracy of the method. Experiments showed that dinitrotoluene is present as both particulate and vapor, that dinitrotoluene can be successfully recovered from alumina, that under high humidity conditions dinitrotoluene is not adsorbed onto the alumina, and that the filter bubbler combination is satisfactory for dinitrotoluene collection. The coefficient of variation is 0.063. Attachments give procedures for generation of organic particulates, test atmospheres, and known humidity of the atmospheres; and a summary of statistical terms and formulas and schematic of sample generation facilities.
Keywords
NIOSH-Author; NIOSH-Analytical-Method; Standards; Standards-Completion-Program; SCP; Analytical-Method; Sampling; Set-3; Air-quality-measurement; Explosives; Nitro-compounds; Organic-solvents; Air-sampling;
CAS No.
121-14-2;
Publication Date
19771101
Fiscal Year
1978
NTIS Accession No.
NTIS Price
Identifying No.
S215
NIOSH Division
DPSE;
Source Name
Division of Physical Sciences and Engineering, NIOSH, Cincinnati, Ohio, 17 pages, 2 references