Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

The evaluation of gas detector tube systems: trichloroethylene.

Authors
Roper-P
Source
Cincinnati, OH: U.S. Department of Health, Education, and Welfare, Health Services and Mental Health Administration, National Institute for Occupational Safety and Health, RR-22, 1972 Jul; :1-16
Link
NIOSHTIC No.
00047925
Abstract
A performance study was conducted to determine the reliability of trichloroethylene (79016) detector tubes. Tubes representing all those available in the United States were tested at concentrations of one-half, one, two, and three times the threshold limit value. Of the 4 brands of tubes evaluated, only one was acceptable, the Drager No. CH-244 10/a.
Keywords
NIOSH-Author; Chlorinated-hydrocarbons; Analytical-methods; Measurement-instrumentation; Air-contaminants
CAS No.
79-01-6
Publication Date
19720701
Document Type
Other
Fiscal Year
1972
NTIS Accession No.
PB93-142040
NTIS Price
A03
Identifying No.
RR-22
NIOSH Division
OD
Source Name
National Institute for Occupational Safety and Health
State
OH
TOP