The evaluation of gas detector tube systems: nitrogen dioxide.

Authors
Brown-CH Jr.
Source
Cincinnati, OH: U.S. Department of Health, Education, and Welfare, Health Services and Mental Health Administration, National Institute for Occupational Safety and Health, RR-20, 1972 Jun; :1-16
Link
NIOSHTIC No.
00033051
Abstract
Reliability testing by NIOSH of nitrogen dioxide gas detector tubes from five manufacturers, with gas generated at standard concentrations relative to the threshold limit value (TLV) by a dynamic permeation tube method, concentrations being verified analytically by the Saltzman technique. The performance requirement of plus or minus 25% accuracy at the 95% confidence level at one, two, and five times the TLV, and at plus or minus 35% at one-half the TLV is met by only the Drager CH 30000.5950 detector tube.
Keywords
Gas-detectors; Performance-tests; Measurement-instrumentation; Monitoring-equipment; Samplers; Air-quality-control; Toxic-gases
CAS No.
10102-44-0
Publication Date
19720629
Document Type
Other
Fiscal Year
1972
NTIS Accession No.
PB93-142057
NTIS Price
A03
Identifying No.
RR-20
NIOSH Division
OD
Source Name
National Institute for Occupational Safety and Health
State
OH