Title: Antibody to Cytomegalovirus IgG (Surplus Sera)
(SSCMV_A
)
Contact Number: 1-866-441-NCHS
Years of Content: 1999
- 2000
First Published: March, 2008
Revised:
NA
Access Constraints: None
Use Constraints: None
Geographic Coverage: National
Subject:Antibody to Cytomegalovirus IgG
Record Source: NHANES 1999
- 2000
Survey Methodology: NHANES 1999
- 2000
is a stratified multistage probability sample of the civilian non-institutionalized population of the U.S.
Medium: NHANES Web site; SAS transport files
Cytomegalovirus (CMV) antibody testing of stored sera specimens from NHANES 1999-2004 was conducted to estimate the seroprevalence of CMV infection (CMV IgG) in participants aged 6 to 49 years. An optical density measure for IgG is also included in this data release as an estimate of antibody titer.
Participants aged 6 to 49 years from NHANES 1999-2004 with stored sera (N = 15,336).
CMV specific IgG was measured with an ELISA by Quest International, Inc., Miami FL. Sera with values near the ELISA cutoff (approx 5.2% of total) were confirmed with a second ELISA assay by bioMerieux, Inc., Durham, NC. When the results from these 2 tests disagreed (approx. 2.7% of total), an IFA from Bion International, Inc., was used and the result of the IFA was given as the final result.
Optical Density for the IgG test is reported. Optical density was measured with the ELISA assay by Quest International, Inc. and approximately corresponds to antibody titer; a low and positive optical density indicates low antibody titer and a high optical density indicates high antibody titer.
Data were received after all the antibody testing was complete. The data were not edited.
Data Access: All data are publicly available.
Commercial reagents were used for all CMV testing. All QC procedures recommended by the manufacturers were followed.
There are two variables:
SSCMV: CMV specific IgG results (1=Positive, 2=Negative,
3= Equivocal)
SSCMVOD: CMV IgG Optical Density from the ELISA by Quest International, Inc., Miami FL. Measured in AU/ml which stands for Arbitrary units/ml. Continuous variable - Values range from 0.048 to 3.001. Values reported as “out of range” (i.e. over the detectable range, > 3.00) were assigned values of 3.001.
| Code or Value | Value Description | Count | Cumulative | Skip to Item |
|---|---|---|---|---|
| 0.078 to 3.001 | Range of Values | 4656 | 4656 | |
| . | Missing | 0 | 4656 |
| Code or Value | Value Description | Count | Cumulative | Skip to Item |
|---|---|---|---|---|
| 1 | Positive | 2791 | 2791 | |
| 2 | Negative | 1865 | 4656 | |
| 3 | Equivocal | 0 | 4656 | |
| . | Missing | 0 | 4656 |